FC/APC Fiber Optic Patch Cords
FC/APC Fiber Optic Patch Cords
It is possible to be equipped with the outer pieces likeFC, SC and LC, etc. With respect to UPC and PC, have less losses of insertionand more losses of return.
Use
• Communications network of fiber
• Network of access of fiber broadband
• CATV of fiber
• Fiber instruments
• LAN of fiber
Components
• Inserted nucleus: nucleus inserted ceramic of zirconium of NSK, high qualityand great intensity, made in
• External pieces: diverse national NSK, AMP, MOLEX, fabrication
• Cable: Measured
Indices
Model | Loss of insertion (standard international) | Loss of insertion (company) | Loss of insertion (typical) | Loss of return (standard international) | Loss of return (company) | Loss of return (typical) |
PC | ≦0.3dB | ≦0.2dB | ≦0.1dB | ≧40 dB | ≧45 dB | ≧45 dB |
UPC | ≦0.3dB | ≦0.2dB | ≦0.1dB | ≧45 dB | ≧50 dB | ≧50 dB |
APC | ≦0.3dB | ≦0.2dB | ≦0.2dB | ≧60 dB | ≧65 dB | ≧65 dB |
Conditions
Programs conditions |
Aging temperatura85ºC, 85% relative humidity, 14 days changes of the loss of insertion ≤0.1dB |
Circulation of the temperature -40ºC~ 75ºC, 10%-80% relative humidity, 42 circulations, 14 days changes of the loss of insertion ≤0.1dB |
Immersion of the water temperature 43ºC, PH5.5, 7 days changes of the loss of inserción≤0.1dB |
Vibration amplitude |
Flexion of load |
Load return |
Resistance to the tension |
Impact |
Reference Bell-core TA-NWT-001209 changes of the loss of insertion ≤0.1dB |